Plating Thickness Calculator

Figures denote time in hours and minutes to deposit required thickness at given current densities.

 

AT 10 AMPERES PER SQUARE FOOT

Thickness

in Inches

.0001

.0002

.0004

.0006

.0008

.001

Cadmium

6

12

24

35

46.7

58

Copper

(Acid)

10.5

21.5

43.5

65.5

85

109

Copper

(Cyanide)

5.33

10.5

21

31

42

53

Tin

(Stannate)

12

23.5

47

70

94

120

Tin (Acid)

4.7

9.4

18.8

28.2

37.5

46.9

Zinc

8

16.5

33

50

66

88

Nickel

12

24

48

72

96

120

Home

AT 20 AMPERES PER SQUARE FOOT

Thickness in Inches

.0001

.0002

.0004

.0006

.0008

.001

Cadmium

3

6

12

17.5

23.1

29

Copper

(Acid)

5.3

10.75

22

32.5

43

54.5

Copper

(Cyanide)

2.5

5.3

10.5

17

23

27

Tin

(Stannate)

6

12

23.5

35.25

47

59

Tin (Acid)

2.35

4.7

9.4

14.1

18.8

23.5

Zinc

4

8.25

16.5

25

33

44

Nickel

6.66

12

24

36

48

59

 

AT 30 AMPS PER SQUARE FOOT

Thickness

in Inches

.0001

.0002

.0004

.0006

.0008

.001

Cadmium

2

4

8

12

16

19

Copper

(Acid)

3.5

7.33

14.5

22

28

36

Copper

(Cyanide)

1.66

3.5

7.5

10.5

14

18

Tin

(Stannate)

4

8

16

23.5

31.25

39

Tin (Acid)

1.57

3.14

6.28

9.42

12.56

15.7

Zinc

2.75

5.33

10.66

16.5

22

28

Nickel

4

8

16

24

32

40

 

AT 40 AMPERES PER SQUARE FOOT

Thickness

in Inches

.0001

.0002

.0004

.0006

.0008

.001

Cadmium

1.25

3

6

8.75

12

15

Copper

(Acid)

2.66

5.5

10.66

16.3

22

27

Copper

(Cyanide)

1.33

2.5

5.33

8

10.5

13

Tin

(Stannate)

3

6

12

18

23.5

29.25

Tin (Acid)

1.2

2.3

4.7

7

9.4

11.7

Zinc

2

4

8.25

12.5

16.5

22

Nickel

3

6

12

18

24

29

 

Cadmium based on 100% cathode efficiency.

Copper (acid) based on 97% cathode efficiency.

Copper (cyanide) based on 100% cathode efficiency.

Tin (stannate) based on 80% cathode efficiency.

Nickel based on 95% cathode efficiency.

Tin (acid) based on 98% efficiency

Zinc based on 92% efficiency